Remeha Gas 210 Ace

Remeha Gas 210 Ace Floor Standing Boilers - Commercial Boilers
Remeha-by-Baxi

Floor Standing Boilers

Remeha Gas 210 Ace

A compact, lightweight structure makes the Remeha Gas 210 Ace floor standing boiler quick and easy to install.


It has the capacity to be installed back-to-back, which provides added flexibility in space-saving design. The optional secondary return feature makes this boiler particularly suitable with heating technologies that use low-grade heat, such as heat pumps or underfloor circuits.

Features and Benefits

High-efficiency 

High-efficiency floor standing boiler up to 95.8% GCV Seasonal Efficiency – reliable, high-performance operation

    Compact size

    Extremely compact dimensions and ability to be installed back-to-back – space-saving solution, ideally suited for modular configurations

      Environmentally friendly

      Low Class 6 NOx emission levels from 33mg/kWh (0% O2 dry) – low pollutant emissions meeting all environmental legislation 

        Energy efficient

        Options for direct weather compensation – close matching of heat demand at all times for maximum energy efficiency

          Maximum efficiencies

          Optional secondary return feature – maximum efficiencies with low-grade heat technologies

            Easy operation

            Digital diagnostic display and remote signalling options – easy operaion and maintenance 
              Show More
              Show Less

              Product Literature

              Installation & Service Manuals

              Installation & Service Manuals

              Product Documentation

              No documentation available.

              Specification Guides

              Specification Guides

              Product Documentation

              No documentation available.

              Product Fiche

              Product Fiche

              Product Documentation

              No documentation available.

              Energy Labels

              Energy Labels

              Product Documentation

              No documentation available.

              BIM Files

              BIM Files

              Product Documentation

              No documentation available.

              CAD Files

              CAD Files

              Product Documentation

              No documentation available.

              Remeha-Gas-210-Ace-Dimensions

              Dimensions

              80kW - 200kW

              Boiler Width = 1190mm
              Boiler Height = 1368mm
              Boiler Depth = 450mm

              Technical Specification

              Remeha Gas 210 Ace80120160200
              3 sections 4 sections 5 sections 6 sections
              Performance
              Nominal heat output central heating operation @ 80/60°C kW (min-max)18-8722-12029-16639-200
              Nominal heat output central heating operation @ 50/30°C kW (min-max)20-9324-12933-17944-217
              Nominal input (Hi) (min-max)19-8923-12331-17041-205
              Efficiency
              SBEM seasonal efficiency GCV95.8%95.66%95.5%95.74%
              Efficiency – full load 100% NCV97.4%97.5%97.5%97.6%
              Efficiency – part load 30% NCV108.6%108.1%108.3%108.4%
              Eco design useful efficiency @ 80/60°C (100% full load) GCV87.7%87.8%87.8%87.8%
              Eco design useful efficiency @ 50/30°C (30% part load) GCV97.7%97.5%97.3%97.6%
              Gas
              Standard fuelNatural gasNatural gasNatural gasNatural gas
              Optional fuel adjustment – see installation & service manualLPG (propane)LPG (propane)LPG (propane)LPG (propane)
              Max gas consumption NG m3/h9.4131821.7
              Max gas consumption LPG m3/h3.64.878.4
              Min/max gas inlet pressure NG mbar17-2517-2517-2517-25
              Min/max gas pressure LPG mbar37-5037-5037-5037-50
              Gas connection size BSP inches1¼” male thread1¼” male thread1¼” male thread1½” male thread
              Flame protectionIonisationIonisationIonisationIonisation
              IgnitionElectronicElectronicElectronicElectronic
              Flue (concentric connection supplied as standard)
              Flue diameter mm I/D150150150150
              Air inlet diameter mm I/D150150150150
              Mass flue gas flow rate kg/h27-15037-19739-28765-345
              Max counter pressure PA130130130130
              Hydraulics
              Water content litres12162024
              Hydraulic resistance @ 11°C ΔT mbar549449566599
              Hydraulic resistance @ 20°C ΔT mbar165135170180
              Nominal flow rate @11°C ΔT l/s1.892.613.614.33
              Nominal flow rate @ 20°C ΔT l/s1.041.431.982.38
              Minimum flow rate I/hr1120148621422585
              Condensate connection32mm OD32mm OD32mm OD32mm OD
              Connection size BSP1¼” male thread1¼” male thread1¼” male thread1½” male thread*
              Standard operating temperature °C20-9020-9020-9020-90
              Max operating temperature °C90909090
              Max water temperature °C110110110110
              Max water operating pressure bar6666
              Min water operating pressure bar0.80.80.80.8
              General
              Dry weight kg115135165188
              Dimension (WxHxD)1190 x 1368 x 4501190 x 1368 x 4501190 x 1368 x 4501190 x 1368 x 450
              NOx (Dry, 0% 02) Mg/kWh56494452
              Noise levels dB(A) at 1 metre Less than 59 Less than 59 Less than 59 Less than 59
              Eco design sound power levels LWA indoors dB67676767
              Standby heat Loss0.210.210.210.21
              Electrical
              Nominal power supply230v x 1Ph x 50hz230v x 1Ph x 50hz230v x 1Ph x 50hz230v x 1Ph x 50hz
              Start current amps26-10328-16749-19648-306
              Modulating input V dc0-100-100-100-10
              Fuse rating amps6.36.36.36.3
              Controls voltage24 (max 4va)24 (max 4va)24 (max 4va)24 (max 4va)
              Insulation class IPIPX1**IPX1**IPX1**IPX1**

              * with supplied 1¼" > 1½" reducer bushings
              **IP20 when appliance is fitted with a B23 conventional flue

              How can we help?

              Contact us to speak to one of our experts